Making medical facilities safer and more attractive
|
Targets- a wide range for design is kept
- the freedom of use is guaranteed
- no interference with the conveyor system
- by means of a competent consultation to the development
- unlimited lifetime and waranty emphasised through maintenance agreements
|
|
|
1. Automatic textile smoke curtains for passagess |
 |
- How can you fulfil the demands of safe smoke extraction concepts in areas where smoke barriers close
all the way down to the floor level - especially if there are requests for escape possibilities? - Smoke barrier Stripecoil with CE-label
Creation of smoke compartments in escape routes respectively in areas where the smoke barrier is closed down to the floor level and persons and hospital beds have to pass and to be passed through the system. The Stripecoil system is available in drop length up to 3,5 m with a twin coil system for unlimited width. The frequency of persons passing through the smoke barriers is at approx. 200/minute at a width of 3 m.
|
2. Smoke curtains with a curved course |
 |
3. Automatic smoke barrier made of a fabric |
 |
- How you can make sure that the smoke will not be spread out though large openings by the
elevator shaft from one floor to the next or from one room to the next? Or how can be sealed smoke tight large openings in accordance with DIN 18095 or EN 1634-3? - Smoke protection closure Fiberseal Evolution-Sa or -Sm, Fiberseal-H, Fiberseal-S in accordance with
DIN EN 1634-3. Secure, large scale smoke colsures even at high pressure loads (50 pa) and temperatures up to 200°C. Due to the small architectural design, highest demands are covered (“Invisible fire protection”). Optionally smoke protection closures can be designed as fire protection closures.
|
4. Creation of areas to guide smoke or as fire protection closure |
 |
- How can the existing high demands on tightness of smoke barriers be fulfilled? Or how can a fire
protection closure for a room in prestigious buildings be adjusted to the architecture? No limitation by side guides or pillars can be accepted? - Smoke guiding: Smokeshield-S Fire protection closure: Fibershield-S
Smoke protection closure Smokeshield-S offers a polygon shaped design. No disturbing side guides are necessary to achieve the requested tightness. Due to the flat design, the systems can be perfectly integrated into ceilings and are available in extremely large widths and lengths where the angels may vary from +/- 90° (30° - 150°).
|
5. Automatic textile fire protection closures for nurses’ lounges / reception desks |
 |
- Openings of nurses’ lounges must be sealed off in case of danger so that in case of fire in nurse’ lounge
there will be no effect in the floor. - Fire protection closure Fibershield Room
These automatic systems are very small and can be well integrated in the architecture. Depending on fire protection classification it can be choosen between E- and EW-classification (“ Invisible fire protection ”).
|
6. Automatic fire protection closures made of a fabric – to seal openings in walls |
 |
- How is it possible to seal openings in an architecturally appealing environment with fire protection
closures which need heat insulating characteristics with the classification El 90 (T 90) while affecting the architecture as less as possible? - Fire protection closure Fibershield-P, Fibershield-E, Fibershield-I and Fibershield-W tested in
accordance with DIN EN 1634-1. These automatic systems are very small and can be well integrated in the architecture. Depending on fire protection classification it can be choosen among the protection targets “E 90 – 180”, “EW 60 – 90” or “EI 30 – EI 60 without water, EI 120 with water”. (“ Invisible fire protection” ).
|
7. Fire protection closures with classification EI without water admission |
 |
- How is it possible to seal openings in an architecturally appealing environment with fire curtains which need heat insulating characteristics with the classification El 90 (T 90) while affecting the architecture as less as possible?
- Fire protection closure “Hidden Shield” - the textile fire protection closure with the classification El 30 / El 90
This closure that meets highest architectural demands and open design concepts, is the first fire protection closure in the world without side guides. Due to the special and structural construction there are no further compensatory actions, such as sprinklers, necessary to reach the textile closures’ protection target
|
8. Automatic textile fire- or smoke protection closures for openings in ceilings |
 |
9. Fire protection hoods for electric devices as screens, snack vending machines |
 |
- When there are screens, snack vending machines or other electrical equipments with a fire load in necessary corridors in the building, it has to be ensured that the fire does not affect the escape. How can the protection be ensured with restriction of the operating procedure?
- Fire protection hood Copy-Cap
Tested fire protection hoods, automatically unfold from picture frames or ceilings and enclose the object with is to be protected. The fire is smothered and the smoke is captured underneath the hood. These hoods can even protect high-quality equipment against forge water (e.g. by activated sprinklers).
|
10. Fire protection closures to close openings in façades – external application |
 |
- If two fire compartments converge at a buildings inside corner or if the distance between the buildings is less
than 3 – 5 meters or the roof of an extension is connected to a wall with openings, it has to be assured that the fire does not spread through the openings in the façade. Which opportunities are there without having to close the openings with masonry? - Fibershield-F
By installations outside of the building, but also on the inside, this protection can be guaranteed. With these automatic sealing systems standard windows without fireproof glazing can be used. These standard windows are operable and therefore do not restrict the room-comfort.
|
11. Conveyor system closure for uninterruped and interrupted conveyor systems |
 |
- Various goods are transported criss-cross through the building by various conveyor systems like roller-, belt-, chain carrying or circular conveyors. Thereby they often break through fire protection compartments.
How can theses openings be sealed in case of fire?
- Conveyor system closures of different series Universal-B, ECClos-FLEX, ECClos-RS, ECClos-S
- The operation is always guaranteed as the cross section of the conveyor system is not affected. The systems - even for large cross sections - can be designed for over or under pressure operation. The conveyor system closures are applicable for dusty, lamellar, sliceable materials.
|
12. CANopen® bus – cross linked hold open units with approval Z-6.5-1990 / 2011 |
 |
- Are cross linked control units (hold open units) with a certificate of usability for smoke doors, fire protection
doors, conveyor systems closures, etc. available? They need to communicate with bus control units, have to protect complex units and need to be handled easily. - Bus control unit RZ-7 BMZ-2 with or without RZ7 locking device
- The bus control unit for Stöbich products as well as for all further brands of smoke and fire protection closures. Using the operator panel, all systems can be controlled and easily be extended. This increases the safety as well as the comfort and reduces the effort for installation.
|
Example of use
Automatic textile smoke curtain for passages
|
|
|
Proof of the feasibility to walk through for persons, wheelchairs and hospital beds
Approval of efficacy of smoke shieldingResult according to test report no. BCL – G 328/10: Smoke at the fire side, visibility approx. 1 m, At the averted fire side, visibility approx. 20 m

|

|

|
Testing laboratory |
Measuring apparatus
|
Testing team |

|

|

|
|
Glance through the stripes in smoky room |
Glance into the chamber during extreme smoke and temperature polution |

|

|
|
Fabric load in the smoky room after the smoke test
|
Fabric load outer the smoky room after the smole test |
|
|
|
 |
|
|
|