Protection concepts of the smoke protection closures


Protection concepts



1. For openings in walls
  • How can large openings in walls be sealed according to smoke protection requirements, although there is only less space available or architectural requirements need to be considered?
  • Smoke protection closure Fiberseal Evolution-Sm, Fiberseal Evolution-Sa
  • These automatic systems are very small and can be integrated architecturally well. Depending on the required smoke classification there can be chosen between the goals of the class Sa or Sm to DIN EN 13501-2. If additional requirements exist with regard to fire resistance class, by a modification of the fabric the protection class to E 120, EW 90 up to EI 120 in conjunction with a water impact can be achieved.


2. For openings in ceilings
  • How can large openings in ceilings that built fire compartments be sealed according to protection targets when there is only limited space available or architectural have to be achieved?
  • Smoke protection closure Fiberseal-H
  • Due to the small construction of these automatic systems little space requirement is necessary and so these can be integrated very well in the architecture. The smoke tightness with class Sa according to DIN EN 13501-2 can be used depending on the fire protection classification and if required, the fire resistance of class E 90 can be reached by modifying the fabric.


3. For compartmentation: a smoke protection closure that goes around the corner!
  • How can you create compartments with smoke protection closures that go around the corner and should not affect the architecture with side guides that are necessary in the corners? Is it possible that the corners of an enclosed polygon can be other than rectangular?
  • Smoke protection closure Fiberseal-S
  • The smoke protection curtain Fiberseal-S offers a polygonal smoke compartimentation without disturbing side guides to reach the desired tightness. The flat casing of the systems can be well integrated in the ceiling. The system can run polygonal whereupon the angles can be between 30° and 150°. The systems have caracteristic protection target of the class Sa according to DIN EN 13501-2.


4. Smoke compartmentation in underground parkings
  • How can large passing openings be sealed - e.g. subdivision of large zones or gateways in consideration of the available space in the lintel and lateral area of the opening?
  • Smoke protection closure Fiberseal Evolution-Sm, Fiberseal Evolution-Sa
  • These automatic systems are very small and can be well integrated. Depending on the requested smoke protection classification you can chose between the target Sa or SM according to DIN 13501-2. If there are additional requirements concerning the fire protection class, the targets of E 120 and EW 90 can be reached by a modification of the fabric as well as the target EI 120 in combination with water discharge.


5. Automatic smoke protection closures in front of elevators
  • How can be secured that smoke won’t be transmitted through elevator shafts from one storey to the next or through large openings from one room to another? Or how can large openings be sealed smoke tight according to DIN 18095 or EN 1634-3?
  • Smoke protection closure Fiberseal Evolution-Sm, Fiberseal Evolution-Sa
  • These automatic systems are very small and can be architecturally well integrated. Depending on the required smoke protection classification you can chose between the target Sa or SM according to DIN 13501-2. If there are additional requirements concerning the fire protection class, the targets of E 120 and EW 90 can be reached by a modification of the fabric as well as the target EI 120 in combination with water discharge. If the systems are free standing the sealing can also be done by the Fiberseal-S (see 3.).


6. Smoke protection closures for drinks- / snacks dispenser or video walls
  • How can security be provided in case of fire when drinks or snacks dispenser are placed in corridor niches or screens are installed to the wall and by this built an additional fire load? Do I have to create a separate room for this?
  • Smoke protection closure Fiberseal Evolution-Sm, Fiberseal Evolution-Sa
  • These automatic systems are very small and can be architecturally well integrated. Depending on the required smoke protection classification you can chose between the target Sa or SM according to DIN 13501-2. If there are additional requirements concerning the fire protection class, the targets of E 120 and EW 90 can be reached by a modification of the fabric as well as the target EI 120 in combination with water discharge. If the systems are free standing the sealing can also be done by the Fiberseal-S (see 3.).


7. Smoke protection closures for nurse's stations or receptions
  • How can sealed partitions in these areas be achieved without disturbing the communications by walls?
  • Smoke protection closure Fiberseal Evolution-Sm, Fiberseal Evolution-Sa
  • These automatic systems are very small and can be architecturally well integrated. Depending on the required smoke protection classification you can chose between the target Sa or SM according to DIN 13501-2. If there are additional requirements concerning the fire protection class, the targets of E 120 and EW 90 can be reached by a modification of the fabric as well as the target EI 120 in combination with water discharge.


8. Separation of endangered zones between kitchen and canteen
  • Is it possible to seal the connection between these areas without high restrictions?
  • Smoke protection closure Fiberseal Evolution-Sm, Fiberseal Evolution-Sa
  • These automatic systems are very small and can be architecturally well integrated. Depending on the required smoke protection classification you can chose between the target Sa or SM according to DIN 13501-2. If there are additional requirements concerning the fire protection class, the targets of E 120 and EW 90 can be reached by a modification of the fabric as well as the target EI 120 in combination with water discharge.